(1) Tee, 0.375” T x 4” X 8” x 4” w/ Double Bevel Weld
(1) Tee, 0.375” T x 4” x 8” x 4” w/ Single Bevel Weld w/ Backing Bar
(1) Tee, 0.5” T x 4” x 8” x 4” w/ Double Fillet Weld
(2) Plates, 0.625” T x 4” x 8” w/ Single V Weld Bevel
(1) Plate, 0.625” T x 4” x 8” w/ Double V Weld Bevel
(1) Plate, 0.375” T x 4” x 8” w/ Single V Weld Bevel
(1) Plate, 0.375” T x 4” x 8” w/ Single V Weld Bevel w/ Backing Bar
(1) Plate, 0.5” T x 4” x 8” w/ Single V Weld Bevel
(1) Pipe, 4” Sch160 (0.5” wall) x 8” w/ Single V Weld Bevel
KIT SPECIFICATIONS:
• Set of 10 Specimens
• Specimen Alloy Mild
• Carbon Steel
• Custom Alloys Available
• Each Specimen will contain 3 flaws
• Total of 30 flaws
• Each specimen contains flaws that are designed to be detectable using multiple NDT methods
• Flaws are detectable by a variety of NDT methods:VT, MT,PT, UT (Conventional & PAUT), RT, and ET. Please note that not all flaws are detectable with every method.
KIT DOCUMENTATION INCLUDES:
• Certificate of Conformance
• As Built CAD Drawings
• UT Inspection Reports
• RT, Digital & Film Radiograph Film and Technician Sheet
• Measuring & Test Equipment Certificates
• Test Sheets (used during technician training and testing)
• Kit Includes 2 Carrying Case(s)